Gas sample probe for sampling from zones with explosive dust
Approval according to ATEX for sampling from dust Ex zones 20, 21 and 22
Approval according to ATEX for mounting in Ex zones 1, 2 or 21, 22
Stainless steel filter element
Sealing material for filter housing lid and flange: graphite
Adaption to nearly all process conditions due to its compact and modular design
Easy installation and low maintenance
Low dead volume
Material of sample-contacting parts: stainless steel, graphite
Selection of pre-filters which are mandatory for the valid Ex approval (pre-filter not included)
Optionally: self-regulating heater, back-purge unit, 2-way or 2/3-way ball valve in the probe inlet, pneumatic actuator for a ball valve, second sample gas outlet, extension tube for pre-filter